Opin vísindi

The Effectiveness of Percutaneous Vertebroplasty is Determined by the Patient-Specific Bone Condition and the Treatment Strategy

Skoða venjulega færslu

dc.contributor Háskólinn í Reykjavík
dc.contributor Reykjavik University
dc.contributor.author Widmer Soyka, René P.
dc.contributor.author Benedikt Helgason
dc.contributor.author Hazrati Marangalou, Javad
dc.contributor.author van den Bergh, Joop P.
dc.contributor.author Rietbergen, Bert van
dc.contributor.author Ferguson, Stephen J.
dc.date.accessioned 2018-10-29T15:18:51Z
dc.date.available 2018-10-29T15:18:51Z
dc.date.issued 2016-04-21
dc.identifier.citation Widmer Soyka RP, Helgason B, Hazrati Marangalou J, van den Bergh JP, Rietbergen Bv, Ferguson SJ (2016) The Effectiveness of Percutaneous Vertebroplasty Is Determined by the Patient-Specific Bone Condition and the Treatment Strategy. PLoS ONE 11(4): e0151680. doi:10.1371/ journal.pone.0151680
dc.identifier.issn 1932-6203
dc.identifier.uri https://hdl.handle.net/20.500.11815/882
dc.description.abstract Vertebral fragility fractures are often treated by injecting bone cement into the collapsed vertebral bodies (vertebroplasty). The mechanisms by which vertebroplasty induces pain relief are not completely understood yet and recent debates cast doubt over the outcome of the procedure. The controversy is intensified by inconsistent results of randomized clinical trials and biomechanical studies that have investigated the effectiveness or the change in bio-mechanical response due to the reinforcement. The purpose of this study was to evaluate the effectiveness of vertebroplasty, by varying the relevant treatment parameters and (a) computationally predicting the improvement of the fracture risk depending on the chosen treatment strategy, and (b) identifying the determinants of a successful treatment.
dc.description.sponsorship Seventh Framework Programme
dc.format.extent e0151680
dc.language.iso en
dc.publisher Public Library of Science (PLoS)
dc.relation info:eu-rep/grantAgreement/EC/ FP7/ICT/223865/VPHOP
dc.relation.ispartofseries Plos One;11(4)
dc.rights info:eu-repo/semantics/openAccess
dc.subject Finite element method
dc.subject Vertebral fractures
dc.subject Osteoporosis compression fractures
dc.subject Vertebroplasty
dc.subject Treatment parameters
dc.subject Beinþynning
dc.subject Beinbrot
dc.subject Meðferð
dc.title The Effectiveness of Percutaneous Vertebroplasty is Determined by the Patient-Specific Bone Condition and the Treatment Strategy
dc.type info:eu-repo/semantics/article
dcterms.license This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
dc.description.version Peer reviewed
dc.identifier.journal Plos One
dc.identifier.doi 10.1371/journal.pone.0151680
dc.relation.url http://dx.plos.org/10.1371/journal.pone.0151680
dc.contributor.school Tækni- og verkfræðideild (HR)
dc.contributor.school School of Science and Engineering (RU)


Skrár

Þetta verk birtist í eftirfarandi safni/söfnum:

Skoða venjulega færslu