Prototype master protocol for benchmarking of real-world follow-up data in glaucoma

dc.contributor.authorHujanen, Pekko
dc.contributor.authorTuulonen, Anja
dc.contributor.authorLeinonen, Sanna
dc.contributor.authorVepsäläinen, Kristian
dc.contributor.authorJóhannesson, Gauti
dc.contributor.authorVaajanen, Anu
dc.contributor.authorLehtonen, Eemil
dc.contributor.authorUusitalo-Jarvinen, Hannele
dc.contributor.departmentFaculty of Medicine
dc.date.accessioned2025-11-20T09:53:17Z
dc.date.available2025-11-20T09:53:17Z
dc.date.issued2025-08
dc.descriptionPublisher Copyright: © 2025 The Author(s). Acta Ophthalmologica published by John Wiley & Sons Ltd on behalf of Acta Ophthalmologica Scandinavica Foundation.en
dc.description.abstractPurpose: The purpose of this study was to create a prototype master protocol for benchmarking glaucoma real-world data (RWD). Benchmarking is part of the digital innovation strategy of the Finnish aces-rwm ecosystem (automation of care and evaluation of the system with real-world monitoring). Methods: We collected glaucoma RWD in 2012–17 at Tampere University Hospital (Tays) and compared them to six published RWD sets (one in Sweden and five in England). Visual field (VF) data at Tays were retrieved from the perimeter, and clinical RWD were collected manually. At baseline, VF data were available in 2511 of 4121 glaucoma patients (61%), of whom 1413 patients (56%) had 5 years of VF follow-up by 2017 (34% of all 4121 patients). Mean deviation (MD) data were analysed in multiple ways, considering also age and intraocular pressure (IOP). Results: In most data sets, higher age was related to faster progression. At Tays, the distributions of progression rates were similar in better and worse eyes. The proportions of eyes at Tays with the medium rate of MD progression (17% for 0.5–1.5 dB/year) and the fast rate (6% for >1.5 dB/year) were similar to the published RWD trial in England. The published datasets show significant variability in how their findings were reported. Conclusions: This study represents a first step toward the development of a master protocol for real-world benchmarking of glaucoma care. Further refinement of the protocol will encourage and require national and international collaboration in order to produce comprehensive and comparable real-world EHR data sets.en
dc.description.versionPeer revieweden
dc.format.extent13
dc.format.extent480276
dc.format.extent539-551
dc.identifier.citationHujanen, P, Tuulonen, A, Leinonen, S, Vepsäläinen, K, Jóhannesson, G, Vaajanen, A, Lehtonen, E & Uusitalo-Jarvinen, H 2025, 'Prototype master protocol for benchmarking of real-world follow-up data in glaucoma', Acta Ophthalmologica, vol. 103, no. 5, pp. 539-551. https://doi.org/10.1111/aos.17453en
dc.identifier.doi10.1111/aos.17453
dc.identifier.issn1755-375X
dc.identifier.other237534312
dc.identifier.othera3387d21-ea9c-4461-8594-07a8e4040ef2
dc.identifier.other85218823774
dc.identifier.otherunpaywall: 10.1111/aos.17453
dc.identifier.other39943889
dc.identifier.urihttps://hdl.handle.net/20.500.11815/7838
dc.language.isoen
dc.relation.ispartofseriesActa Ophthalmologica; 103(5)en
dc.relation.urlhttps://www.scopus.com/pages/publications/85218823774en
dc.rightsinfo:eu-repo/semantics/openAccessen
dc.subjectbenchmarkingen
dc.subjectglaucomaen
dc.subjectmaster protocolen
dc.subjectprogressionen
dc.subjectreal-world dataen
dc.subjectFollow-Up Studiesen
dc.subjectHumansen
dc.subjectMiddle Ageden
dc.subjectMaleen
dc.subjectVisual Fields/physiologyen
dc.subjectGlaucoma/physiopathologyen
dc.subjectDisease Progressionen
dc.subjectIntraocular Pressure/physiologyen
dc.subjectAged, 80 and overen
dc.subjectFemaleen
dc.subjectAdulten
dc.subjectBenchmarking/methodsen
dc.subjectAgeden
dc.subjectVisual Field Testsen
dc.subjectRetrospective Studiesen
dc.subjectOphthalmologyen
dc.titlePrototype master protocol for benchmarking of real-world follow-up data in glaucomaen
dc.type/dk/atira/pure/researchoutput/researchoutputtypes/contributiontojournal/articleen

Skrár

Original bundle

Niðurstöður 1 - 1 af 1
Nafn:
Acta_Ophthalmologica_-_2025_-_Hujanen_-_Prototype_master_protocol_for_benchmarking_of_real_world_follow_up_data_in_glaucoma.pdf
Stærð:
469.02 KB
Snið:
Adobe Portable Document Format

Undirflokkur