Uniaxial and lateral strain behavior of ribbed reinforcement bars inspected with digital image correlation

dc.contributorHáskóli Íslands (HÍ)en_US
dc.contributorUniversity of Iceland (UI)en_US
dc.contributor.authorEiriksson, Haukur
dc.contributor.authorBessason, Bjarni
dc.contributor.authorUnnthorsson, Runar
dc.contributor.departmentUmhverfis- og byggingarverkfræðideild (HÍ)en_US
dc.contributor.departmentFaculty of Civil and Environmental Engineering (UI)en_US
dc.contributor.departmentFaculty of Industrial Eng., Mechanical Eng. and Computer Science (UI)en_US
dc.contributor.departmentIðnaðarverkfræði-, vélaverkfræði- og tölvunarfræðideild (HÍ)en_US
dc.contributor.schoolSchool of Engineering and Natural Sciences (UI)en_US
dc.contributor.schoolVerkfræði- og náttúruvísindasvið (HÍ)en_US
dc.date.accessioned2019-12-05T15:11:14Z
dc.date.available2019-12-05T15:11:14Z
dc.date.issued2018-05-30
dc.descriptionPublisher's version (útgefin grein)en_US
dc.description.abstractKnowledge about the plastic behavior of reinforcement steel bars in reinforced concrete (RC) structures is important, especially for seismic design. This paper presents the results of experimental tests where the main aim was to map the plastic deformations of long ribbed reinforcement bars, both in the axial and lateral directions, in order to provide useful information about the behavior of reinforcement bars inside concrete. The study showed that the digital image correlation (DIC) technique is very suitable for this kind of tests. The uniaxial stress–strain curves for side‐by‐side and different gauge lengths (1d, 3d, 5d, 10d) were identical all the way to the max stress, but after that the segment including the neck dominated the strain development. The Poisson's ratio increased rapidly during the yielding phase to 0.44–0.49 and was constant all the way to rupture. The location of the neck could be predicted at the end of the yielding phase.en_US
dc.description.sponsorshipThis work was supported by a doctoral grant from the Eimskip University Fund of the University of Iceland, by the University of Iceland Research Fund, and by the Ludvigs Storr Trust Fund.en_US
dc.description.versionPeer Revieweden_US
dc.format.extent1992-2003en_US
dc.identifier.citationEiriksson, HJ, Bessason, B, Unnthorsson, R. Uniaxial and lateral strain behavior of ribbed reinforcement bars inspected with digital image correlation. Structural Concrete. 2018; 19: 1992– 2003. https://doi.org/10.1002/suco.201800042en_US
dc.identifier.doi10.1002/suco.201800042
dc.identifier.issn1464-4177
dc.identifier.issn1751-7648 (eISSN)
dc.identifier.journalStructural Concreteen_US
dc.identifier.urihttps://hdl.handle.net/20.500.11815/1372
dc.language.isoenen_US
dc.publisherWiley-Blackwellen_US
dc.relation.ispartofseriesStructural Concrete;19(6)
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectDICen_US
dc.subjectExperimental observationen_US
dc.subjectGauge lengthsen_US
dc.subjectLateral strainen_US
dc.subjectLüder's behavioren_US
dc.subjectNeckingen_US
dc.subjectPoisson's ratioen_US
dc.subjectRibbed reinforcement barsen_US
dc.subjectStress–strain curvesen_US
dc.subjectByggingarverkfræðien_US
dc.subjectBurðarþolen_US
dc.titleUniaxial and lateral strain behavior of ribbed reinforcement bars inspected with digital image correlationen_US
dc.typeinfo:eu-repo/semantics/articleen_US
dcterms.licenseThis is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.en_US

Skrár

Original bundle

Niðurstöður 1 - 1 af 1
Hleð...
Thumbnail Image
Nafn:
Eiriksson_et_al-2018-Structural_Concrete.pdf
Stærð:
14.81 MB
Snið:
Adobe Portable Document Format
Description:
Publisher´s version

Undirflokkur