Replacement of traditional prothrombin time monitoring with the new Fiix prothrombin time increases the efficacy of warfarin without increasing bleeding. A review article

dc.contributor.authorÖnundarson, Páll Torfi
dc.contributor.authorPalsson, Ragnar
dc.contributor.authorWitt, Daniel M.
dc.contributor.authorGudmundsdottir, Brynja R.
dc.contributor.departmentFaculty of Medicine
dc.date.accessioned2025-11-20T08:34:53Z
dc.date.available2025-11-20T08:34:53Z
dc.date.issued2021-10-15
dc.descriptionPublisher Copyright: © 2021, The Author(s). Supported by the RANNIS technology development fund (The Icelandic Center for Research, rannis@rannis.is). The funding source had no contribution to the scientific work or writing of the text.en
dc.description.abstractThe antithrombotic effect of vitamin K antagonists (VKA) depends on controlled lowering of the activity of factors (F) II and X whereas reductions in FVII and FIX play little role. PT-INR based monitoring, however, is highly influenced by FVII, which has the shortest half-life of vitamin K-dependent coagulation factors. Hence, variability in the anticoagulant effect of VKA may be partly secondary to an inherent flaw of the traditional monitoring test itself. The Fiix prothrombin time (Fiix-PT) is a novel test that is only sensitive to reductions in FII and FX and is intended to stabilize the VKA effect. Two clinical studies have now demonstrated that when warfarin is monitored with the Fiix-PT based normalized ratio (Fiix-NR) instead of PT-INR, anticoagulation is stabilized and less testing and fewer dose adjustments are needed. Furthermore, the relative risk of thromboembolism was reduced by 50–56% in these studies without an increase in major bleeding.en
dc.description.versionPeer revieweden
dc.format.extent1773878
dc.format.extent72
dc.identifier.citationÖnundarson, P T, Palsson, R, Witt, D M & Gudmundsdottir, B R 2021, 'Replacement of traditional prothrombin time monitoring with the new Fiix prothrombin time increases the efficacy of warfarin without increasing bleeding. A review article', Thrombosis Journal, vol. 19, no. 1, 72, pp. 72. https://doi.org/10.1186/s12959-021-00327-1en
dc.identifier.doi10.1186/s12959-021-00327-1
dc.identifier.issn1477-9560
dc.identifier.other42836272
dc.identifier.other8d6a4f07-9612-4768-8cc7-19550cea9908
dc.identifier.other85117358890
dc.identifier.other34654442
dc.identifier.other000707586100001
dc.identifier.urihttps://hdl.handle.net/20.500.11815/6530
dc.language.isoen
dc.relation.ispartofseriesThrombosis Journal; 19(1)en
dc.relation.urlhttps://www.scopus.com/pages/publications/85117358890en
dc.rightsinfo:eu-repo/semantics/openAccessen
dc.subjectFiixen
dc.subjectMonitoringen
dc.subjectOral anticoagulationen
dc.subjectProthrombin timeen
dc.subjectWarfarinen
dc.subjectHematologyen
dc.titleReplacement of traditional prothrombin time monitoring with the new Fiix prothrombin time increases the efficacy of warfarin without increasing bleeding. A review articleen
dc.type/dk/atira/pure/researchoutput/researchoutputtypes/contributiontojournal/systematicreviewen

Skrár

Original bundle

Niðurstöður 1 - 1 af 1
Nafn:
s12959_021_00327_1_1_.pdf
Stærð:
1.69 MB
Snið:
Adobe Portable Document Format

Undirflokkur