Opin vísindi

Optimization and validation of a UPLC-MS/MS assay for simultaneous quantification of 2,8-dihydroxyadenine, adenine, allopurinol, oxypurinol and febuxostat in human plasma

Optimization and validation of a UPLC-MS/MS assay for simultaneous quantification of 2,8-dihydroxyadenine, adenine, allopurinol, oxypurinol and febuxostat in human plasma


Titill: Optimization and validation of a UPLC-MS/MS assay for simultaneous quantification of 2,8-dihydroxyadenine, adenine, allopurinol, oxypurinol and febuxostat in human plasma
Höfundur: Thorsteinsdottir, Unnur A
Runólfsdóttir, Hrafnhildur L.
Eiríksson, Finnur Freyr
Ágústsd., Inger María Schweitz
Eðvarðsson, Viðar Örn
Pálsson, Runólfur
Þorsteinsdóttir, Margrét
Útgáfa: 2024-03-01
Tungumál: Enska
Umfang: 1372986
Háskóli/Stofnun: Landspitali - The National University Hospital of Iceland
Svið: Health Sciences
Deild: Other departments
Faculty of Medicine
Faculty of Pharmaceutical Sciences
Birtist í: Journal of Chromatography B: Analytical Technologies in the Biomedical and Life Sciences; 1235()
ISSN: 1570-0232
DOI: 10.1016/j.jchromb.2024.124041
Efnisorð: Barnahjúkrun; Barnalæknisfræði; Nýrnalæknisfræði; Adenine phosphoribosyltransferase (APRT) deficiency; Clinical mass spectrometry; Design of experiments (DoE); Diagnosis; Pharmacotherapy monitoring; Rare kidney stone diseases; Validation; Adenine/metabolism; Urolithiasis; Febuxostat; Humans; Tandem Mass Spectrometry/methods; Metabolism, Inborn Errors; Renal Insufficiency, Chronic/drug therapy; Adenine Phosphoribosyltransferase/metabolism; Allopurinol/therapeutic use; Chromatography, Liquid; Oxypurinol; Liquid Chromatography-Mass Spectrometry; Analytical Chemistry; Biochemistry; Clinical Biochemistry; Cell Biology
URI: https://hdl.handle.net/20.500.11815/4730

Skoða fulla færslu

Tilvitnun:

Thorsteinsdottir , U A , Runólfsdóttir , H L , Eiríksson , F F , Ágústsd. , I M S , Eðvarðsson , V Ö , Pálsson , R & Þorsteinsdóttir , M 2024 , ' Optimization and validation of a UPLC-MS/MS assay for simultaneous quantification of 2,8-dihydroxyadenine, adenine, allopurinol, oxypurinol and febuxostat in human plasma ' , Journal of Chromatography B: Analytical Technologies in the Biomedical and Life Sciences , vol. 1235 , 124041 , pp. 124041 . https://doi.org/10.1016/j.jchromb.2024.124041

Útdráttur:

Adenine phosphoribosyltransferase (APRT) deficiency is a rare , hereditary disorder characterized by renal excretion of 2,8-dihydroxyadenine (DHA), leading to kidney stone formation and chronic kidney disease (CKD). Treatment with a xanthine oxidoreductase inhibitor, allopurinol or febuxostat, reduces urinary DHA excretion and slows the progression of CKD. The method currently used for therapeutic monitoring of APRT deficiency lacks specificity and thus, a more reliable measurement technique is needed. In this study, an ultra-performance liquid chromatography-tandem mass spectrometry method for simultaneous quantification of DHA, adenine, allopurinol, oxypurinol and febuxostat in human plasma was optimized and validated. Plasma samples were prepared with protein precipitation using acetonitrile followed by evaporation. The chemometric approach design of experiments was implemented to optimize gradient steepness, amount of organic solvent, flow rate, column temperature, cone voltage, desolvation temperature and desolvation flow rate. Experimental screening was conducted using fractional factorial design with addition of complementary experiments at the axial points for optimization of peak area, peak resolution and peak width. The assay was validated according to the US Food and Drug Administration guidelines for bioanalytical method validation over the concentration range of 50 to 5000 ng/mL for DHA, allopurinol and febuxostat, 100 to 5000 ng/mL for adenine and 50 to 12,000 ng/mL for oxypurinol, with r2 ≥ 0.99. The analytical assay achieved acceptable performance of accuracy (-10.8 to 8.3 %) and precision (CV < 15 %). DHA, adenine, allopurinol, oxypurinol and febuxostat were stable in plasma samples after five freeze-thaw cycles at -80 °C and after storage at -80 °C for 12 months. The assay was evaluated for quantification of the five analytes in clinical plasma samples from six APRT deficiency patients and proved to be both efficient and accurate. The proposed assay will be valuable for guiding pharmacotherapy and thereby contribute to improved and more personalized care for patients with APRT deficiency.

Athugasemdir:

Copyright © 2024 The Author(s). Published by Elsevier B.V. All rights reserved.

Skrár

Þetta verk birtist í eftirfarandi safni/söfnum: