Thermal hysteresis analysis of finned-heat-pipe-assisted latent heat thermal energy storage application for solar water heater system

dc.contributor.authorBazri, Shahab
dc.contributor.authorBadruddin, Irfan Anjum
dc.contributor.authorUsmani, Abdullah Yousuf
dc.contributor.authorAnwar Khan, Saleem
dc.contributor.authorKamangar, Sarfaraz
dc.contributor.authorNaghavi, Mohammad Sajad
dc.contributor.authorRahman Mallah, Abdul
dc.contributor.authorAbdelrazek, Ali H.
dc.date.accessioned2026-10-30T09:51:00Z
dc.date.available2026-10-30T09:51:00Z
dc.date.issued2022-12
dc.descriptionPublisher Copyright: © 2022 Elsevier Ltd. All rights reserved.en
dc.description.abstractThis work numerically investigates the performance of an innovative compact-design solar water heater (SWH) using evacuated tube heat pipe solar collectors (ETHPSCs) coupled with a latent heat storage tank (LHS tank). This system is thought to be an unwritten fourth generation of solar water heaters known as heat-pipe-assisted thermal batteries. The basic and explicit hypothesis is to store energy than a bulk of hot water, which is the key distinction in compared to the prior classical sorts. Using three phase change materials (PCMs) for high and low solar intensity categories in the tropical region of South East Asia, a computational effort is conducted to model the system and the given temperature headed for the supply output hot water. This research is validated by two interrelated experimental and analytical investigations. According to the results of 12-h charging (melting) process, the maximum mean temperature of the PCMs belongs to PCM C, Rubitherm (RT70HC), which indicates 101 °C during the defined typical high daily solar radiation. This value implies 2.02% error in compared to the reference study. Referring to the solid-liquid interface parameter, the maximum liquefied thickness is also for PCM C with 76 mm thickness. However, reaching the complete melting is required by further studies.en
dc.description.versionPeer revieweden
dc.format.extent9775762
dc.format.extent
dc.identifier.citationBazri, S, Badruddin, I A, Usmani, A Y, Anwar Khan, S, Kamangar, S, Naghavi, M S, Rahman Mallah, A & Abdelrazek, A H 2022, 'Thermal hysteresis analysis of finned-heat-pipe-assisted latent heat thermal energy storage application for solar water heater system', Case Studies in Thermal Engineering, vol. 40, 102490. https://doi.org/10.1016/j.csite.2022.102490en
dc.identifier.doi10.1016/j.csite.2022.102490
dc.identifier.issn2214-157X
dc.identifier.other251497070
dc.identifier.other20992e92-c933-48cd-b32d-a8a6ee9c47f5
dc.identifier.other85141678465
dc.identifier.urihttps://hdl.handle.net/20.500.11815/8981
dc.language.isoen
dc.relation.ispartofseriesCase Studies in Thermal Engineering; 40()en
dc.relation.urlhttps://www.scopus.com/pages/publications/85141678465en
dc.rightsinfo:eu-repo/semantics/openAccessen
dc.subjectHeat pipeen
dc.subjectLatent heat thermal energy storageen
dc.subjectMeltingen
dc.subjectPhase change materialen
dc.subjectSolar water heateren
dc.subjectEngineering (miscellaneous)en
dc.subjectFluid Flow and Transfer Processesen
dc.titleThermal hysteresis analysis of finned-heat-pipe-assisted latent heat thermal energy storage application for solar water heater systemen