Geothermal fluid extraction and injection-related fracture slip susceptibility and seismicity in naturally fractured rocks
Dagsetning
Höfundar
Journal Title
Journal ISSN
Volume Title
Útgefandi
Útdráttur
Understanding fracture slip susceptibility in geothermal reservoirs is central to the control of fluid injection-induced seismicity. To investigate the role of regional fracture systems on induced seismicity, a coupled thermo-hydro-mechanical (THM) model containing fracture networks was developed, which features direct coupling between different physics for explicit fractures, fractured rocks (porous matrix blocks with small-scale fractures) and their interactions, as well as indirect coupling through changes of material properties, such as stress-dependent fracture and rock permeabilities. The model was applied to simulate geothermal fluid extraction and re-injection in a natural fracture system comprised of three dominant fracture sets at the Hellisheiði geothermal field over a 10-year period (2011–2021), utilising field recorded monthly production and re-injection rates. Based on the model results, the slip susceptibility of regional fracture systems was examined under reservoir conditions before and after the start of fluid re-injection across different time scales, i.e., over short (1 month), intermediate (1 year) and long-term (10 years). Two model scenarios, one with cooling contraction and one without, were considered to examine the relative contribution of cooling contraction and fluid overpressure on fracture slip susceptibility. Results have shown that fracture networks act as preferential fluid flow paths that influence fluid pressure and stress distribution and fracture slip susceptibility in geothermal reservoirs. NE-SW and N-S trending fractures at Hellisheiði are susceptible to slippage before the start of fluid re-injection. During fluid re-injection, the distribution of fractures with enhanced slip susceptibility gradually shifts from surrounding the re-injection region to forming a two-lobed pattern in the fault-normal direction around the re-injection region, indicating the dominant role of cooling contraction over fluid overpressure on the fracture slip susceptibility in the intermediate- and long-term.
Lýsing
Publisher Copyright: © 2024 The Authors
Efnisorð
Cooling contraction, Fluid overpressure, Fracture system, Geothermal exploitation, Induced seismicity, Thermo-hydro-mechanical coupling, Geotechnical Engineering and Engineering Geology
Citation
Cao, W, Durucan, S, Shi, J Q, Korre, A, Ratouis, T & Hjörleifsdóttir, V 2024, 'Geothermal fluid extraction and injection-related fracture slip susceptibility and seismicity in naturally fractured rocks', International Journal of Rock Mechanics and Mining Sciences, vol. 183, 105939. https://doi.org/10.1016/j.ijrmms.2024.105939