The dynamic evolution of the Lahendong geothermal system in North-Sulawesi, Indonesia

dc.contributor.authorSuherlina, Lily
dc.contributor.authorNewson, Juliet
dc.contributor.authorKamah, Yustin
dc.contributor.authorBrehme, Maren
dc.date.accessioned2026-10-29T14:59:01Z
dc.date.available2026-10-29T14:59:01Z
dc.date.issued2022-11
dc.descriptionPublisher Copyright: © 2022 The Author(s)en
dc.description.abstractThis study uses an integrated approach to characterize the dynamic evolution of the power-producing high-enthalpy geothermal system of Lahendong, North-Sulawesi, Indonesia. Lahendong has two primary reservoirs, the southern and the northern, which have been utilised for electricity production for more than twenty years. The main focus of this study is the characterisation of heat and mass flows in the system with respect to geological structures and permeability distribution. Also, it delineates how the geothermal system has evolved and the spatial variation of the response resulting from prolonged utilization of the reservoirs. This research implemented geological structure analysis on recent surface fault mapping and pre-existing fault studies from literature. Further, the study analysed well data comprising well pressure, enthalpy, drilling program reviews and tracer tests. Hydrochemical investigation compiled new and old surface and subsurface hydrochemical evolution in both the temporal and spatial domain. The results confirm several fault trends in the study area: NE-SW and NW-SE are the major striking directions, while E-W and N-S are less dominant. The most apparent trends are NE-SW striking strike-slip faults, NW-SE thrust faults and N-S and E-W striking normal faults. The faults compartmentalize the reservoir. A comparison of the southern and the northern reservoir shows that the southern one is more controlled by faults; both reservoirs rely on fractures as permeability provider and are controlled by shallow hydrogeology, as derived from the integrated analysis of transient well data. Geochemical analysis shows that the reservoir fluids have generally a higher eelectrical conductivity and are closer to fluid-rock equilibrium, probably due to boiling, compared to spring waters. Spring waters have generally become more acidic, which is an expected result of reservoir boiling and increased steam input to near-surface waters. The spatial distribution of changes shows a permeability evolution over time and also the role of structural permeability in response to changing reservoir conditions. Observing and recording reservoir data is highly important to understand the reservoir response to production and ensure the long-term sustainability of the system. Additionally, the data is critical for making a major difference in the reservoir management strategy.en
dc.description.versionPeer revieweden
dc.format.extent26337999
dc.format.extent
dc.identifier.citationSuherlina, L, Newson, J, Kamah, Y & Brehme, M 2022, 'The dynamic evolution of the Lahendong geothermal system in North-Sulawesi, Indonesia', Geothermics, vol. 105, 102510. https://doi.org/10.1016/j.geothermics.2022.102510en
dc.identifier.doi10.1016/j.geothermics.2022.102510
dc.identifier.issn0375-6505
dc.identifier.other251494087
dc.identifier.other387fe261-9ac9-4eb6-b114-31213f4f4f2c
dc.identifier.other85134581081
dc.identifier.urihttps://hdl.handle.net/20.500.11815/8974
dc.language.isoen
dc.relation.ispartofseriesGeothermics; 105()en
dc.relation.urlhttps://www.scopus.com/pages/publications/85134581081en
dc.rightsinfo:eu-repo/semantics/openAccessen
dc.subjectFluid dynamicsen
dc.subjectHigh enthalpy systemen
dc.subjectHydrochemistryen
dc.subjectPermeability changesen
dc.subjectStructural controlsen
dc.subjectWell behaviouren
dc.subjectRenewable Energy, Sustainability and the Environmenten
dc.subjectGeotechnical Engineering and Engineering Geologyen
dc.subjectGeologyen
dc.titleThe dynamic evolution of the Lahendong geothermal system in North-Sulawesi, Indonesiaen
dc.type/dk/atira/pure/researchoutput/researchoutputtypes/contributiontojournal/articleen

Skrár

Original bundle

Niðurstöður 1 - 1 af 1
Nafn:
1-s2.0-S0375650522001572-main.pdf
Stærð:
25.12 MB
Snið:
Adobe Portable Document Format