Multifrequency microwave imaging for brain stroke detection

dc.contributor.authorWang, Lulu
dc.contributor.departmentDepartment of Engineering
dc.date.accessioned2026-10-01T11:09:00Z
dc.date.available2026-10-01T11:09:00Z
dc.date.issued2020
dc.descriptionPublisher Copyright: © 2020 Tech Science Press. All rights reserved.en
dc.description.abstractCT and MRI are often used in the diagnosis and monitoring of stroke. However, they are expensive, time-consuming, produce ionizing radiation (CT), and not suitable for continuous monitoring stroke. Microwave imaging (MI) has been extensively investigated for identifying several types of human organs, including breast, brain, lung, liver, and gastric. The authors recently developed a holographic microwave imaging (HMI) algorithm for biological object detection. However, this method has difficulty in providing accurate information on embedded small inclusions. This paper describes the feasibility of the use of a multifrequency HMI algorithm for brain stroke detection. A numerical system, including HMI data collection model and a realistic head model, was developed to demonstrate the proposed method for imaging of brain tissues. Various experiments were carried out to evaluate the performance of the proposed method. Results of experiments carried out using multifrequency HMI have been compared with the results obtained from single frequency HMI. Results showed that multifrequency HMI could detect strokes and provide more accurate results of size and location than the single frequency HMI algorithm.en
dc.description.versionPeer revieweden
dc.format.extent8
dc.format.extent476849
dc.format.extent33-40
dc.identifier.citationWang, L 2020, 'Multifrequency microwave imaging for brain stroke detection', MCB Molecular and Cellular Biomechanics, vol. 17, no. 1, pp. 33-40. https://doi.org/10.32604/MCB.2019.07165en
dc.identifier.doi10.32604/MCB.2019.07165
dc.identifier.issn1556-5297
dc.identifier.other251020399
dc.identifier.other30b3adf3-bbfe-4f5f-b28a-e2d0af0b201c
dc.identifier.other85085682090
dc.identifier.urihttps://hdl.handle.net/20.500.11815/8444
dc.language.isoen
dc.relation.ispartofseriesMCB Molecular and Cellular Biomechanics; 17(1)en
dc.relation.urlhttps://www.scopus.com/pages/publications/85085682090en
dc.rightsinfo:eu-repo/semantics/openAccessen
dc.subjectBrain strokeen
dc.subjectDielectric objecten
dc.subjectHolographic microwave imagingen
dc.subjectMicrowave imagingen
dc.subjectBiophysicsen
dc.subjectMolecular Medicineen
dc.subjectMolecular Biologyen
dc.subjectCell Biologyen
dc.titleMultifrequency microwave imaging for brain stroke detectionen
dc.type/dk/atira/pure/researchoutput/researchoutputtypes/contributiontojournal/articleen

Skrár

Original bundle

Niðurstöður 1 - 1 af 1
Nafn:
20200122103623_93844.pdf
Stærð:
465.67 KB
Snið:
Adobe Portable Document Format