Self-applied somnography : technical feasibility of electroencephalography and electro-oculography signal characteristics in sleep staging of suspected sleep-disordered adults

dc.contributor.authorRusanen, Matias
dc.contributor.authorKorkalainen, Henri
dc.contributor.authorGrétarsdóttir, Heiður
dc.contributor.authorSiilak, Tiina
dc.contributor.authorOlafsdottir, Kristin Anna
dc.contributor.authorTöyräs, Juha
dc.contributor.authorMyllymaa, Sami
dc.contributor.authorArnardóttir, Erna Sif
dc.contributor.authorLeppänen, Timo
dc.contributor.authorKainulainen, Samu
dc.contributor.departmentDepartment of Engineering
dc.date.accessioned2025-11-17T08:19:27Z
dc.date.available2025-11-17T08:19:27Z
dc.date.issued2023-07-03
dc.descriptionFunding Information: Financial support for this study was provided by the European Union's Horizon 2020 Research and Innovation Programme under grant agreement No 965417, by the Research Committee of the Kuopio University Hospital Catchment Area for the State Research Funding (Grants 5041807, 5041804, 5041803, 5041797, and 5041794), by the Finnish Cultural Foundation through Kainuu Regional Fund and Central fund, by Olvi Foundation, by the Finnish Anti‐Tuberculosis Association, by Tampere Tuberculosis Foundation, by the Research Foundation of the Pulmonary Diseases, by the NordForsk (NordSleep Project 90458) through the Business Finland (Grant 5133/31/2018), by the Kuopio University Hospital Research Foundation, and The Icelandic Centre for Research. Publisher Copyright: © 2023 The Authors. Journal of Sleep Research published by John Wiley & Sons Ltd on behalf of European Sleep Research Society.en
dc.description.abstractSleep recordings are increasingly being conducted in patients’ homes where patients apply the sensors themselves according to instructions. However, certain sensor types such as cup electrodes used in conventional polysomnography are unfeasible for self-application. To overcome this, self-applied forehead montages with electroencephalography and electro-oculography sensors have been developed. We evaluated the technical feasibility of a self-applied electrode set from Nox Medical (Reykjavik, Iceland) through home sleep recordings of healthy and suspected sleep-disordered adults (n = 174) in the context of sleep staging. Subjects slept with a double setup of conventional type II polysomnography sensors and self-applied forehead sensors. We found that the self-applied electroencephalography and electro-oculography electrodes had acceptable impedance levels but were more prone to losing proper skin–electrode contact than the conventional cup electrodes. Moreover, the forehead electroencephalography signals recorded using the self-applied electrodes expressed lower amplitudes (difference 25.3%–43.9%, p < 0.001) and less absolute power (at 1–40 Hz, p < 0.001) than the polysomnography electroencephalography signals in all sleep stages. However, the signals recorded with the self-applied electroencephalography electrodes expressed more relative power (p < 0.001) at very low frequencies (0.3–1.0 Hz) in all sleep stages. The electro-oculography signals recorded with the self-applied electrodes expressed comparable characteristics with standard electro-oculography. In conclusion, the results support the technical feasibility of the self-applied electroencephalography and electro-oculography for sleep staging in home sleep recordings, after adjustment for amplitude differences, especially for scoring Stage N3 sleep.en
dc.description.versionPeer revieweden
dc.format.extent2421657
dc.format.extent
dc.identifier.citationRusanen, M, Korkalainen, H, Grétarsdóttir, H, Siilak, T, Olafsdottir, K A, Töyräs, J, Myllymaa, S, Arnardóttir, E S, Leppänen, T & Kainulainen, S 2023, 'Self-applied somnography : technical feasibility of electroencephalography and electro-oculography signal characteristics in sleep staging of suspected sleep-disordered adults', Journal of Sleep Research. https://doi.org/10.1111/jsr.13977en
dc.identifier.doi10.1111/jsr.13977
dc.identifier.issn0962-1105
dc.identifier.other172187205
dc.identifier.other9b117afe-62d5-4f05-beeb-0d48a3e35cc2
dc.identifier.other85164208096
dc.identifier.otherunpaywall: 10.1111/jsr.13977
dc.identifier.urihttps://hdl.handle.net/20.500.11815/6040
dc.language.isoen
dc.relation.ispartofseriesJournal of Sleep Research; ()en
dc.relation.urlhttps://www.scopus.com/pages/publications/85164208096en
dc.rightsinfo:eu-repo/semantics/openAccessen
dc.subjecthome sleep apnea testingen
dc.subjectportable diagnosticsen
dc.subjectsleep-disordered breathingen
dc.subjectCognitive Neuroscienceen
dc.subjectBehavioral Neuroscienceen
dc.titleSelf-applied somnography : technical feasibility of electroencephalography and electro-oculography signal characteristics in sleep staging of suspected sleep-disordered adultsen
dc.type/dk/atira/pure/researchoutput/researchoutputtypes/contributiontojournal/articleen

Skrár

Original bundle

Niðurstöður 1 - 1 af 1
Nafn:
Journal_of_Sleep_Research_-_2023_-_Rusanen.pdf
Stærð:
2.31 MB
Snið:
Adobe Portable Document Format