Compact eucapnic voluntary hyperpnoea apparatus for exercise-induced respiratory disease detection

dc.contributor.authorWang, Lulu
dc.contributor.authorAl-Jumaily, Ahmed
dc.contributor.departmentDepartment of Engineering
dc.date.accessioned2026-09-23T15:01:01Z
dc.date.available2026-09-23T15:01:01Z
dc.date.issued2017-05-16
dc.descriptionPublisher Copyright: © 2017 by the authors. Licensee MDPI, Basel, Switzerland.en
dc.description.abstractEucapnic voluntary hyperpnoea (EVH) challenge provides objective criteria for exercise-induced asthma (EIA) or exercise-induced bronchoconstriction (EIB), and it was recommended to justify the use of inhaled β2-agonists by athletes for the Olympics. This paper presents the development of a compact and easy-to-use EVH apparatus for assessing EIB in human subjects. The compact apparatus has been validated on human subjects and the results have been compared to the conventional EVH system. Twenty-two swimmers, including eleven healthy subjects and eleven subjects who had been physician-diagnosed with asthma, were recruited from sport and recreation centers throughout Auckland, New Zealand. Each subject performed two EVH challenge tests using the proposed breathing apparatus and the conventional Phillips EVH apparatus on separate days, respectively. Forced expiratory volume in one second (FEV1) was measured before and after the challenges. A reduction in FEV1 of 10% or more was considered positive. Of the eleven subjects who were previously diagnosed with asthma, EIB was present in all subjects (100%) in the compact EVH group, while it was presented in ten subjects (90.91%) in the conventional EVH challenge group. Of the eleven healthy subjects, EIB was present in one subject (4.55%) in the compact EVH group, while it was not present in the conventional EVH group. Experimental results showed that the compact EVH system has potential to become an alternative tool for EIB detection.en
dc.description.versionPeer revieweden
dc.format.extent757809
dc.format.extent
dc.identifier.citationWang, L & Al-Jumaily, A 2017, 'Compact eucapnic voluntary hyperpnoea apparatus for exercise-induced respiratory disease detection', Sensors (Switzerland), vol. 17, no. 5, 1139. https://doi.org/10.3390/s17051139en
dc.identifier.doi10.3390/s17051139
dc.identifier.issn1424-8220
dc.identifier.other251014184
dc.identifier.othere49d4e75-1af7-466b-a8c9-a919175a8d00
dc.identifier.other85019607129
dc.identifier.other28509868
dc.identifier.urihttps://hdl.handle.net/20.500.11815/8332
dc.language.isoen
dc.relation.ispartofseriesSensors (Switzerland); 17(5)en
dc.relation.urlhttps://www.scopus.com/pages/publications/85019607129en
dc.rightsinfo:eu-repo/semantics/openAccessen
dc.subjectBronchoprovocation techniqueen
dc.subjectEucapnic voluntary hyperpnoeaen
dc.subjectEucapnic voluntary hyperventilationen
dc.subjectExercise-induced asthmaen
dc.subjectExercise-induced bronchoconstrictionen
dc.subjectMaximum voluntary ventilationen
dc.subjectAnalytical Chemistryen
dc.subjectInformation Systemsen
dc.subjectAtomic and Molecular Physics, and Opticsen
dc.subjectBiochemistryen
dc.subjectInstrumentationen
dc.subjectElectrical and Electronic Engineeringen
dc.titleCompact eucapnic voluntary hyperpnoea apparatus for exercise-induced respiratory disease detectionen
dc.type/dk/atira/pure/researchoutput/researchoutputtypes/contributiontojournal/articleen

Skrár

Original bundle

Niðurstöður 1 - 1 af 1
Nafn:
sensors-17-01139-with-cover.pdf
Stærð:
740.05 KB
Snið:
Adobe Portable Document Format