Opin vísindi

Ultrasound examination of the pelvic floor during active labor : A longitudinal cohort study

Show simple item record

dc.contributor.author Eggebø, Torbjørn M.
dc.contributor.author Benediktsdóttir, Sigurlaug
dc.contributor.author Hjartardóttir, Hulda
dc.contributor.author Salvesen, Kjell
dc.contributor.author Volløyhaug, Ingrid
dc.date.accessioned 2023-08-15T01:07:07Z
dc.date.available 2023-08-15T01:07:07Z
dc.date.issued 2023-09
dc.identifier.citation Eggebø , T M , Benediktsdóttir , S , Hjartardóttir , H , Salvesen , K & Volløyhaug , I 2023 , ' Ultrasound examination of the pelvic floor during active labor : A longitudinal cohort study ' , Acta Obstetricia et Gynecologica Scandinavica , vol. 102 , no. 9 , pp. 1203-1209 . https://doi.org/10.1111/aogs.14620
dc.identifier.issn 0001-6349
dc.identifier.other 173674426
dc.identifier.other 5633a0d6-6090-4782-b426-9fcdb5cbb513
dc.identifier.other 85164485799
dc.identifier.other 37417688
dc.identifier.uri https://hdl.handle.net/20.500.11815/4419
dc.description Publisher Copyright: © 2023 The Authors. Acta Obstetricia et Gynecologica Scandinavica published by John Wiley & Sons Ltd on behalf of Nordic Federation of Societies of Obstetrics and Gynecology (NFOG). © 2023 The Authors. Acta Obstetricia et Gynecologica Scandinavica published by John Wiley & Sons Ltd on behalf of Nordic Federation of Societies of Obstetrics and Gynecology (NFOG).
dc.description.abstract INTRODUCTION: There is limited evidence about changes in the pelvic floor during active labor. We aimed to investigate changes in hiatal dimensions during the active first stage of labor and associations with fetal descent and head position. MATERIAL AND METHODS: We conducted a longitudinal, prospective cohort study at the National University Hospital of Iceland, from 2016 to 2018. Nulliparous women with spontaneous onset of labor, a single fetus in cephalic presentation, and gestational age ≥37 weeks were eligible. Fetal position was assessed with transabdominal ultrasound and fetal descent was measured with transperineal ultrasound. Three-dimensional volumes were acquired from transperineal scanning at the start of the active phase of labor and in late first stage or early second stage. The largest transverse hiatal diameter was measured in the plane of minimal hiatal dimensions. The levator urethral gap was measured as the distance between the center of the urethra and the levator insertion using tomographic ultrasound imaging. Measurements of the levator urethral gap were made in the plane of minimal hiatal dimensions and 2.5 and 5 mm cranial to this. RESULTS: The final study population comprised 78 women. The mean transverse hiatal diameter increased 12.4% between the two examinations, from 39.4 ± 4.1 mm (±standard deviation) at the first examination to 44.3 ± 5.8 mm at the last examination (p < 0.01). We found a moderate correlation between the transverse hiatal diameter and fetal station at the last examination (r = 0.44, r 2  = 0.19; p < 0.01; regression equation y = 2.71 + 0.014x), and a weak correlation between the change in transverse hiatal diameter and change in fetal station (r = 0.29; r 2  = 0.08; p = 0.01; regression equation y = 0.24 + 0.012x). Levator urethral gap increased significantly in all three planes on both the left and right sides. Head position was not associated with hiatal measurements after adjusting for fetal station. CONCLUSIONS: We found a significant, but only modest, increase of the hiatal dimensions during the first stage of labor. The risk of levator ani trauma will therefore be low during this stage. The change in transverse hiatal diameter was associated with fetal descent but not with head position.
dc.format.extent 7
dc.format.extent 1486075
dc.format.extent 1203-1209
dc.language.iso en
dc.relation.ispartofseries Acta Obstetricia et Gynecologica Scandinavica; 102(9)
dc.rights info:eu-repo/semantics/openAccess
dc.subject Fæðinga- og kvensjúkdómafræði
dc.subject birth
dc.subject fetal descent
dc.subject head position
dc.subject hiatal dimensions
dc.subject injury
dc.subject labor
dc.subject levator ani
dc.subject obstetrics
dc.subject pelvic floor
dc.subject prolapse
dc.subject ultrasound
dc.subject urogynecology
dc.subject Prospective Studies
dc.subject Humans
dc.subject Infant
dc.subject Pregnancy
dc.subject Delivery, Obstetric
dc.subject Ultrasonography
dc.subject Female
dc.subject Pelvic Floor/diagnostic imaging
dc.subject Imaging, Three-Dimensional
dc.subject Longitudinal Studies
dc.subject Obstetrics and Gynecology
dc.title Ultrasound examination of the pelvic floor during active labor : A longitudinal cohort study
dc.type /dk/atira/pure/researchoutput/researchoutputtypes/contributiontojournal/article
dc.description.version Peer reviewed
dc.identifier.doi 10.1111/aogs.14620
dc.relation.url http://www.scopus.com/inward/record.url?scp=85164485799&partnerID=8YFLogxK
dc.contributor.department Other departments


Files in this item

This item appears in the following Collection(s)

Show simple item record