Háskóli ÍslandsUniversity of IcelandElias, Said2019-04-082019-04-082018-10-18Elias, S. (2018). Seismic Energy Assessment of Buildings with Tuned Vibration Absorbers. Shock and Vibration, 2018, 10. doi:10.1155/2018/20516871070-96221875-9203 (eISSN)https://hdl.handle.net/20.500.11815/1096Publisher's version (útgefin grein)Seismic analysis and energy assessment of building installed with distributed tuned vibration absorbers (d-TVAs) are presented. The performance of d-TVAs is compared with single tuned vibration absorber (STVA) installed at the top of the building. The placements of the d-TVAs are based on the modal properties of the uncontrolled and controlled buildings. The governing equations of motion of the building with the STVA and d-TVAs are solved by employing Newmark’s integration method. Various energies under earthquake ground excitations are computed to study the effectiveness of using the STVA and d-TVAs. It is concluded that the use of the d-TVAs is the most competent because it effectively dissipates the seismic energy, and they are convenient to install requiring reduced space, as are placed at various floors.2051687eninfo:eu-repo/semantics/openAccessJarðskjálftaverkfræðiByggingarverkfræðiSeismic Energy Assessment of Buildings with Tuned Vibration Absorbersinfo:eu-repo/semantics/articleShock and Vibration10.1155/2018/2051687