Opin vísindi

Replacement of traditional prothrombin time monitoring with the new Fiix prothrombin time increases the efficacy of warfarin without increasing bleeding. A review article

Skoða venjulega færslu

dc.contributor.author Önundarson, Páll Torfi
dc.contributor.author Palsson, Ragnar
dc.contributor.author Witt, Daniel M.
dc.contributor.author Gudmundsdottir, Brynja R.
dc.date.accessioned 2022-04-30T01:03:40Z
dc.date.available 2022-04-30T01:03:40Z
dc.date.issued 2021-10-15
dc.identifier.citation Önundarson , P T , Palsson , R , Witt , D M & Gudmundsdottir , B R 2021 , ' Replacement of traditional prothrombin time monitoring with the new Fiix prothrombin time increases the efficacy of warfarin without increasing bleeding. A review article ' , Thrombosis Journal , vol. 19 , no. 1 , 72 , pp. 72 . https://doi.org/10.1186/s12959-021-00327-1
dc.identifier.issn 1477-9560
dc.identifier.other 42836272
dc.identifier.other 8d6a4f07-9612-4768-8cc7-19550cea9908
dc.identifier.other 85117358890
dc.identifier.other 34654442
dc.identifier.other 000707586100001
dc.identifier.uri https://hdl.handle.net/20.500.11815/3112
dc.description Publisher Copyright: © 2021, The Author(s). Supported by the RANNIS technology development fund (The Icelandic Center for Research, rannis@rannis.is). The funding source had no contribution to the scientific work or writing of the text.
dc.description.abstract The antithrombotic effect of vitamin K antagonists (VKA) depends on controlled lowering of the activity of factors (F) II and X whereas reductions in FVII and FIX play little role. PT-INR based monitoring, however, is highly influenced by FVII, which has the shortest half-life of vitamin K-dependent coagulation factors. Hence, variability in the anticoagulant effect of VKA may be partly secondary to an inherent flaw of the traditional monitoring test itself. The Fiix prothrombin time (Fiix-PT) is a novel test that is only sensitive to reductions in FII and FX and is intended to stabilize the VKA effect. Two clinical studies have now demonstrated that when warfarin is monitored with the Fiix-PT based normalized ratio (Fiix-NR) instead of PT-INR, anticoagulation is stabilized and less testing and fewer dose adjustments are needed. Furthermore, the relative risk of thromboembolism was reduced by 50–56% in these studies without an increase in major bleeding.
dc.format.extent 1773878
dc.format.extent 72
dc.language.iso en
dc.relation.ispartofseries Thrombosis Journal; 19(1)
dc.rights info:eu-repo/semantics/openAccess
dc.subject Blóðþynningarlyf
dc.subject Fiix
dc.subject Monitoring
dc.subject Oral anticoagulation
dc.subject Prothrombin time
dc.subject Warfarin
dc.subject Hematology
dc.title Replacement of traditional prothrombin time monitoring with the new Fiix prothrombin time increases the efficacy of warfarin without increasing bleeding. A review article
dc.type /dk/atira/pure/researchoutput/researchoutputtypes/contributiontojournal/systematicreview
dc.description.version Peer reviewed
dc.identifier.doi 10.1186/s12959-021-00327-1
dc.relation.url http://www.scopus.com/inward/record.url?scp=85117358890&partnerID=8YFLogxK
dc.contributor.department Faculty of Medicine
dc.contributor.department Clinical Laboratory Services, Diagnostics and Blood Bank


Skrár

Þetta verk birtist í eftirfarandi safni/söfnum:

Skoða venjulega færslu